HPRW15 fuse
Product Details:
| Usage | High Voltage |
|---|---|
| Safety Standards | IEC |
| Breaking Capacity | High |
| Place of Origin | Zhejiang, China |
| Brand Name | sunrise electrical appliances |
| Model Number | HPRW15 |
Payment & Shipping Terms:
| Packaging Details: | Each package contains three (one group) fuse; anti-collision panel is fit among every three fuses. Fuse in paper package |
|---|
Detailed Product Description
2. Application ambient conditions
a. The altitude: ≤1000m;
b. The ambient air temperature: -40 min, +40 max, and difference of day temperature should not more than 35;
c. The wind speed: ≤35m/s;
d. Dirty class: III class (porcelain support insulator), IV class (synthetic rubber support insulator);
e. The place without pollution, exploding danger, chemistry corrosive and acute vibration.
3. Reference standard
GB15166.3-1994 Alternating-current high voltage fuse part 3---spraying fuse
GB/T11022-1999 Common specifications for high-voltage switchgear and controlgear standards
GB/T311.1-1997 Insulation cooperation of high voltage power transmission and transformer equipments
4. Description of type
The max breaking current (kA) Rated current (A) Rated voltage (kV) Design series number Outdoor Fuse Spraying Synthetic rubber support insulator |
5. Main technical parameterssee table 1
Table 1 Rated Parameters of Fuse
No. | Item | Unit | Parameters |
1 | Rated voltage | KV | 12 |
2 | Rated frequency | HZ | 50 |
3 | Rated current (the base of fuse) | A | 100/200 |
4 | Rated current of fuse-link equippedfilament | A | 6200 |
5 | Rated short-circuit breaking current (max breaking current) | KA | 12.5 |
6 | Power frequency withstand voltage (1min): wet test / dry test (between phases, phase to earth) / disconnected break | KV | 34/42/48 |
7 | Lightning impulse withstand voltage: between phases, phase to earth / disconnected break | KV | 75/85 |
8 | Mechanical life | Times | 500 |
6. Structure of the fusesee figure 1
The fuse is composed of support insulator, installation board (the size is shown in figure 2), active contact, upper static contact, upper connection terminal, fuse tube (fuse-carrier), bottom static contact, bottom connection terminal and so on.
Figure 1. Structure of the fuse
Bottom connection terminal |
Installation board |
Fuse tube |
Bottom static contact |
Support insulator |
Upper connection terminal |
Active contact |
Upper static contact |
Figure 2. The size of installation board
7. Operating principle
The fuse is in series to the power line when it is in operation, in normal operation, fuse-link (filament) makes active joint of bottom active contact in fuse tube (fuse-carrier) be locked, fuse tube (fuse-carrier) is closed under the press force of static contact spring. When fault is occurred in system, fault current make fuse-link melt rapidly, arc comes into being in arc-extinguishing tube. Aerogenous material mounted in fuse tube and assistant arc-extinguishing tube in fuse-element generate a large number of gases at the action of arc, then enough pressure is formed in fuse tube, and strong longitudinal magnetic field comes into being in the fuse tube and keep arc elongating rapidly, arc will be extinguished when the current reaches zero. After fuse-element has been melted, active joint is released, the fuse tube falls off quickly and forms clear disconnected distance at the action of spring pressure of upper and bottom static contact and the weight itself.
HPRW15 fuse
Other Products from this Supplier
See more
drop-out fuse, high voltage fuse, spraying fuse products from this supplier.
Product Showcase[30]
Company Info
Sunrise Group Co., Ltd.
[China]
[Verified Member]
Online Postings: Products
Business Type:Manufacturer
City: Ningbo
Province/State: Zhejiang
Country/Region : China